Operation
Rogue™ R1 Spot User Manual Rev. 5 -13-
Address
This programming level sets the DMX starting address.
Starting from the Main Level screen, select Address, press <ENTER>.
Set the
DMX Address
In this mode, each product will respond to a unique starting address from the DMX
controller. All products with the same starting address will respond in unison.
This option
sets the products DMX address.
Change the starting address (001512), press <ENTER>.
Run Mode
This programming level sets the DMX personality and controls the different test modes.
Starting from the Main Level screen, select Run Mode, press <ENTER>.
DMX Personality
This option selects which DMX Personality the product uses.
1. Highlight DMX, press <ENTER>.
2. Select the DMX personality 16CH or 19CH, press <ENTER>.
See the DMX Values section for the highest starting address you can select for
each personality.
Make sure that the starting addresses on the various products do not overlap
due to the new personality setting.
Auto Test
This option runs every attribute individually through 1 cycle.
Highlight Auto Test, press <ENTER>.
The Auto Test will end after 1 full cycle. You can stop the test by pressing <MENU>
at any time.
Manual Test
This option allows you to run each attribute individually or as a group.
1. Highlight Manual Test, press <ENTER>.
2. Highlight the desired attribute listed on the control panel screen, press <ENTER>.
Set the attribute value (000255), press <ENTER>.
3. Repeat step 2 for the other attributes.
When exiting the Manual Test level, the values of all tested channels will go back
to zero.