Page 8 of 12 MotionFade™ LED User Manual (Rev. 10)
4. OPERATION
Control Panel
Operation
To access
the control panel functions, use the four buttons located underneath the
display. Please refer to the Product Overview (page 5
) to see the buttons location on the
control panel.
Button
Function
<MENU>
Press to find an operation mode or to back out of the current menu
option
<ENTER>
Press to activate a menu option or a selected value
<UP>
Press to scroll up the list of options or to find a higher value
<DOWN> Press to scroll down the list of options or to find a lower value
Menu Map
Mode Programming Steps Description
Version Software Version Shows the software version number
Automatic
NO
Disables unit’s auto mode function
YES Enables unit’s auto mode function
Sound
NO Disables unit’s sound mode function
YES Enables unit’s sound mode function
DMX Mode
NO Disables unit’s DMX512 mode function
YES 1~512
Enables unit’s DMX512 mode and sets
starting address
Speed 1~9
Selects how fast the auto mode program
runs
Program 1~30
NO
Disables numbered program running in
sequence in auto or sound mode
YES
Enables numbered program running in
sequence in auto or sound mode
Configuration
(DMX)
Set this product in DMX mode to control with a DMX controller.
1. Connect the product to a suitable power outlet.
2. Turn the product on.
3. Connect a DMX cable from the DMX output of the DMX controller to the DMX input
socket of the product.
Starting Address
When selecting a starting DMX address, always consider the number of DMX channels
the selected DMX mode uses. If you
choose a starting address that is too high, you
could restrict the access to some of the products channels.
The MotionFaçade™ LED uses up to 8 DMX channels in its 8-channel DMX mode,
which defines the highest configurable address to 505.
If you are not familiar with the DMX protocol,
download the DMX Primer from
www.chauvetlighting.com.
To select the starting address, do the following:
1. Press <MENU> repeatedly until Dmx512 shows on the display.
2. Press <ENTER>.
3. Press <UP> to select Yes in the menu.
4. Press <ENTER>. Address should appear on the screen.
5. Use <UP> or <DOWN> to select the starting address.
6. Press <ENTER>.