Scorpion™ GBC User Manual 23 August 2011
Product Linking
You will need a serial data link to run light shows of one or more products using a DMX controller or
to run synchronized shows on two or more products set to a master/slave operating mode. The
combined number of channels required by all the products on a serial data link determines the
number of products the data link can support.
Products on a serial data link must be daisy chained in one single line. To comply with the
EIA-485 standard, no more than 32 products should be connected on one data link.
Connecting more than 32 products on one serial data link without the use of a DMX
optically-isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended serial data link distance: 500 m (1640 ft)
Maximum recommended number of products on a serial data link: 32
Setting the Starting Address
This DMX mode enables the use of a universal DMX controller device. Each product requires a
start address from 1~512. A product requiring one or more channels for control begins to read the
data on the channel indicated by the start address. For example, a product that uses six DMX
channels and was addressed to start on DMX channel 100, would read data from channels: 100,
101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap,
and note the start address selected for future reference.
If this is your first time addressing a product using the DMX control protocol, we suggest jumping to
the “Appendix” section and reading the heading “DMX Primer”. It contains very useful information