LED PAR 38-18UV User Manual 11 Rev. 2
Custom Static Intensity
This fixture has the ability to accept custom static intensity. This is accessed via the control panel. Please
see the instructions below for further explanation.
1. Press <MENU> until
U-- appears on the LED screen.
2. Using <UP> and <DOWN>, select the desired intensity value, from lowest to highest (
000~100).
By selecting
000, the output will remain off.
3. Press <ENTER> to save the final color setting.
Fixture Linking
In order to use this fixture in a DMX or master/slave operation, you must daisy chain, using DMX cables to link
from one fixture to another. In a master/slave operation, the DMX controller is not connected.
DMX Channel Values
1
Dimmer
Intensity: 0%~100%
2
000 015
No Function
link out
(only in DMX
operation)