5. TECHNICAL INFORMATION
Fixture
Maintenance
Dust build up reduces light output performance and can cause overheating. This can
lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum
performance and minimize wear, you should clean your lighting fixtures at least twice a
month. However, be aware that usage and environmental conditions could be
contributing factors to increase the cleaning frequency.
To clean this fixture, follow the instructions below:
Unplug the fixture from power.
Wait until the fixture is cold.
Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on
the external surface/vents.
Clean the lens with a mild soap solution, ammonia-free glass cleaner, or isopropyl
alcohol.
Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
Softly drag any dirt or grime to the outside of the lens.
Gently polish the lens until it is free of haze and lint.
Always dry the lens carefully after cleaning it.