3. SETUP
AC Power
The Scorpion™ 3D RGB has an auto-
ranging power supply and it can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker,
power outlet, and
wiring), use the current value listed on the label affixed to the product’s back panel, or
refer to the product’s specifications chart. The listed current rating indicates the
product’s average current draw under normal conditions.
Always connect the product to a protected circuit
(circuit breaker or fuse).
Make sure the product has
an appropriate electrical ground to avoid the
risk of electrocution or fire.
Never connect the product to
a rheostat (variable resistor) or dimmer
circuit, even if the rheostat or dimmer channel serves only as a 0~
100%
switch.
Fuse
Replacement
Disconnect the product from power before replacing the fuse.
Always replace a blown fuse with a fuse of the same type and rating.
1. Unplug the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the fuse holder out of the housing.
4. Remove the blown fuse from the holder.
5. Replace with a fuse of the exact same type and rating.
6. Insert the fuse holder back in place and reconnect power.
The product does not ship with a spare fuse; however, the safety cap has
room for a spare.
Installed fuse
(held by plastic clip)
Spare fuse holder
(inside safety cap)