Page 10 of 26 Scorpion™ Scan RGB EU User Manual (Rev. 01c)
3.
S
ETUP
AC Power
This product has an auto-ranging power supply and it can work with an input voltage
range of 100~240 VAC, 50/60 Hz.
To determine the power requirements for a particular fixture, see the label affixed to
the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s
listed current rating indicates its average current draw under normal conditions.
Always connect this product to a protected circuit (circuit breaker or fuse),
making sure that it has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect this product to a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse
Replacement
This product uses a T (time delay) or S (low blow) 1.6 A, 250 V fuse. Follow the
instructions below to change it.
Disconnect this product from the power outlet before replacing the fuse.
1) Wedge the tip of a flat head screwdriver into the slot of the fuse holder and pry the
safety cap out of its housing.
2) Remove the blown fuse from the plastic clip and replace it with a fuse of the exact
same type and rating.
3) Insert the safety cap with the new fuse back into its place, and reconnect power.
Although the safety cap does have room for a spare fuse, this product ships
with no spare fuse.