4. OPERATION
Control Panel
Operation
To access the control panel functions, use the four buttons located underneath the
display. Please refer to the Product Overview to see the button locations
on the control
panel.
Button Function
<MODE/ESC>
Press to find an operation mode or to back out of the current menu
option
<UP>
Press to scroll up the list of options or to find a higher value
<DOWN>
Press to scroll down the list of options or to find a lower value
<ENTER>
Press to activate a menu option or a selected value
Menu Map
Menu Programming Steps Description
DMX Mode
d001
d001512
DMX starting address
Standalone
Mode
NASL
SLAu
SoN
Standalone: Slave receive mode
NStS
SrUn
Standalone: Sound-Active
NAFA
FASt
Standalone: Auto Program
Pan Invert PAN rPAN
Pan invert
Tilt Invert tit rtit
Tilt invert
Display Invert diS rdiS
Invert the display
DMX Personality 11CH
8CH
8-channel DMX personality
11CH
11-channel DMX personality
Reset rESt
Reset all motors to correct any errors
with motors misaligning during operation
Load Default LoAd
Revert all settings back to the factory
default
Configuration
(DMX)
Set the product in DMX mode to control with a DMX controller.
1. Connect the product to a suitable power outlet.
2. Turn the product on.
3. Connect a DMX cable from the DMX output of the DMX controller to the DMX input
socket on the product.
Starting Address
When selecting a starting DMX address, always consider the number of DMX channels
the selected DMX mode uses. If you
choose a starting address that is too high, you could
restrict the access to some of the product’s channels.
The Intimidator™ Scan LED 300 uses up to 11 DMX channels in its 11-Channel DMX
mode, which defines the highest configurable address to 502.
If you are not familiar with the DMX protocol,
download the DMX Primer from the
CHAUVET® website.
To select the starting address, do the following:
1. Press <MODE/ESC> repeatedly until d(001512) shows on the display.
2. Using <UP> and <DOWN>, select the starting address d(001512).
3. Press <MODE/ESC> until one of the DMX personalities appears on the LED screen
(8CH, 11CH). The most recent DMX personality selected will appear.
4. Use <UP> and <DOWN> to change the personality.
5. Press <ENTER>.
If you are not familiar with DMX, download the DMX Primer from
www.chauvetlighting.com
.