Chauvet B-250 Operations Instructions Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
DMX-1655 Manual Version 1.11 17
1717
17
A
B
C
Inserting/Exchanging rotating gobos
Open the cover by loosening the fastening
screw at the sides of the cover. Remove
the O ring w ith tw eezers if available,
insert the new gobo and replace the O
ring.
Lamp replacement
Because of its high internal pressure, there might be a risk that the Discharge lamp
could explode during operation. The lamp emits intense UV radiation which is
harmful to the eyes and skin. The high luminance of the arc can cause severe
damage to the retina if you look directly into the lamp source.
Alw ays switch off the main supply and never handle the lamp or luminaries w hen
it is hot.
Do not touch the bulb with bare hands. If this happens, clean the lamp with
alcohol and w ipe it with a lint free cloth before installation.
The lamp generates UV radiation. Never operate the lamp without appropriate
shielding.
When burning, the lamp operates at high pressure and there is a slight risk of arc
tube rupture. The risk increases w ith age, temperature and improper handling of
the lamp. Do not use the lamp any longer than its specified life.
Make sure the lamp is located in the
center of the reflector for the best spot.
Adjust lamp position by screws A, B
and C.
When replacing lamp, please wait 15 minutes after
powering down to allow the unit cool down!
CAUTION!
Sw itch off device before
exchanging gobos or colors.
CAUTION!
Never unscrew the screws of the
rotating gobo as the ball bearing will
otherw ise be opened!
Page view 16
1 2 ... 12 13 14 15 16 17 18 19

Comments to this Manuals

No comments