Operating Instructions
DMX-50A User Manual 17
Revised: 2006-04-24 15:26:16
Scene Programming (Steps)
INSERT A SCENE
Action
1) Press and hold the PROGRAM button to
enter programming mode.
2) Press the desired CHASE button.
3) Press the TAP DISPLAY to switch the LCD
display to steps view.
4) Use the BANK UP/DOWN buttons to
navigate steps and locate the insert point of
the new scene. The display will read the
step number.
5) Press MIDI/REC button to prepare the
insert.
6) Use the BANK UP/DOWN button to locate
the SCENE.
7) Press the SCENE button that corresponds
to the scene to be inserted.
8) Press MIDI/REC button to insert the scene.
All LEDs will blink.
Notes
I.e. To insert a scene between Steps 05 and 06
navigate using BANK buttons until the display reads
STEP05.
COPY A SCENE
Action
1) Press and hold the PROGRAM button to
enter programming mode.
2) Select the BANK that contains the scene to
be copied using the BANK UP/DOWN
buttons.
3) Press the SCENE button that corresponds
to the scene to be copied.
4) Press MIDI/REC button to copy the scene.
All LEDs will blink.
5) Select the destination BANK that contains
the scene memory to record onto using the
BANK UP/DOWN buttons.
6) Press the desired SCENE button to
complete copy. All LEDs will blink.
Notes
DELETE A SCENE
Action
1) Press and hold the PROGRAM button to
enter programming mode.
2) Select the BANK that contains the scene to
be deleted by using the BANK UP/DOWN
buttons.
3) Press and hold the AUTO DEL button.
4) Press the SCENE button that corresponds
to the scene you want to delete. All LEDs
will blink.
Notes
When deleting a scene the physical location is not
removed, however, all 240 DMX channels available
to the scene will be set to value 0.