Chauvet SlimBANK User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
Page 16 of 19 SlimBANK™ TRI-18 User Manual
Master/Slave
Mode
The Master/Slave mode allows a single SlimBANK™ TRI-18 unit (the “master) to
control the actions of one or more SlimBANK™ TRI-18 units (the “slaves”) without the
need of a DMX controller. The master unit will be set to operate in either an auto
program or Sound-Active mode, while the slave units will be set to operate in Slave
mode. Once set and connected, the slave units will operate in unison with the master
unit.
Configure the units as indicated below.
Slave units:
1. Set the DMX address to d001.
2. Connect the DMX input of the first slave unit to the DMX output of the master unit.
3. Connect the DMX input of the subsequent slave units to the DMX output of the
previous slave unit.
4. Finish setting and connecting all the slave units.
Master unit:
1. Set the master unit to operate in either an auto program or Sound-Active mode.
2. Make the master unit the first unit in the DMX daisy chain.
Configure all the slave units before connecting the master unit to the DMX daisy
chain.
Never connect a DMX controller to a DMX string configured for Master/Slave
operation because the controller may interfere with the signals from the master unit.
Do not connect more than 31 slave units to the master unit.
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19

Comments to this Manuals

No comments