Page 8 of 19 SlimBANK™ TRI-18 User Manual
Power Linking
The product provides power linking via the Edison/IEC outlet located in the front/back of
the unit.
Power Linking
Diagram
You can power link up to 9 SlimBANK™ TRI-18 units on 120 VAC or up to
16 SlimBANK™ TRI-18 units on 230 VAC.
The power linking diagram shown above corresponds to the North American version of
the product ONLY! If using the product in other markets, you must consult with the local
CHAUVET® distributor as power linking connectors and requirements may differ in your
country or region.