Control Panel Lock
This setting enables you to activate or disable the control panel lock, which keeps non-
authorized personnel from changing the product’s settings.
To secure the SETTINGS level only:
1. Go to SERVICE > ACCESS > SETTINGS LOCK.
a. Select ON to require the password to access the level or OFF to allow open
access.
To secure the SERVICE level only:
1. Go to SERVICE > ACCESS > SERVICE LOCK.
a. Select ON to require the password to access the level or OFF to allow open
access.
To secure all levels of the control panel:
1. Go to SETTINGS > DISPLAY LOCK.
a. Select ON to require the password to the control panel or OFF to allow open
access.
When the control panel lock is active, the product will prompt you to enter the password
after 30 seconds of control panel inactivity or after turning on the product.
Password
After being prompted to enter the password:
Press <UP>, <DOWN>, <UP>, <DOWN>, <ENTER>
DMX Personality
This setting allows you to choose a particular DMX personality.
1. Go to the PERSON main level.
2. Select the desired personality (PERSON1, PERSON2, PERSON3, PERSON4, or
PERSON5).
For the highest starting address you can select for each personality, see the DMX
Values section. Verify that the starting addresses on the products do not overlap due to
the new personality setting.
DMX Control
In this mode, each product will respond to a unique starting address from the DMX
controller. All products with the same starting address will respond in unison.
1. Select a DMX personality as shown in DMX Personality
.
2. Set the running mode:
a. Go to the STAND ALONE > RUN main level.
b. Select the DMX 512 programming level.
3. Set the starting address:
a. Go to ADDRESS main level.
b. Select the starting address (
001~512
).
The highest recommended starting address for each DMX mode are as follows:
DMX Mode DMX Address DMX Mode DMX Address
PERSON1
503
PERSON4
492
PERSON2
492
PERSON5
479
PERSON3
505