Freedom™ Par Quad-4 User Manual Rev. 1 Page 7 of 21
3. SETUP
AC Power
The Freedom™ Par Quad-4 has an internal auto-ranging power supply and it can work with an input
voltage range of 100 to 240 VAC, 50/60 Hz.
Always connect the product to a protected
circuit (circuit breaker or fuse). Make sure the product
has an appropriate electrical ground to avoid the risk of electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or
dimmer channel serves only as a 0 to 100% switch.
Fuse
Replacement
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the fuse holder out of the housing.
4. Remove the blown fuse from the holder.
5. Replace with a fuse of the exact same type and rating.
6. Insert the fuse holder back in place and reconnect power.
Disconnect the product from power before replacing the fuse.
Fuse
Replacement
Diagram
Always replace a blown fuse with another of the same type and rating.
A spare fuse is not included; however, the safety cap has room for a spare.
Spare Fuse
holder (inside
safety cap)
Installed Fuse
(held by plastic clip)
Safety
Cap