Intimidator™ Spot LED 450 User Manual Rev. 2 Page 9 of 21
4. OPERATION
Control Panel
Operation
To access the control panel functions, use the four buttons located underneath the
display.
Button Function
<MENU> Selects an operation mode or backs out of the current menu option
<UP> Scrolls up the list of options or selects a higher value
<DOWN>
Scrolls down the list of options or selects a lower value
<ENTER> Activates a menu option or a selected value
Menu Map
Main Level
Programming Level
Description
DMX Address 001512 Sets the DMX starting address
Run
Slave Slave operating mode
Fast Automatic mode, fast program
Slow Automatic mode, slow program
Sound Sound-Active mode
Pan
Normal
Normal pan operation
Reverse
Reverse pan operation
Tilt
Normal Normal tilt operation
Reverse Reverse tilt operation
Display
Bright Display backlight remains on
30Close
Display backlight turns off after 30
seconds of control panel inactivity
Pan Angle
540 Pan angle range 540°
360
Pan angle range 360°
180 Pan angle range 180°
Tilt Angle
270
Tilt angle range 270°
180
Tilt angle range 180°
90 Tilt angle range 90°
Channel
ADVANCED 14-channel mode
Basic 8-channel mode
Temp. Disp
T1__, T2__, T3__
Displays LED temperature
ResetSystem
No Does not reset fixture
Ok Resets fixture
Load Set
No Does not load factory defaults
Ok Loads factory defaults
Page view 8